Irradiator Modification and Experimental Box Delivery for the Řež Research Centre 

 

The delivery for the Řež Research Centre, where equipment is being tested for radiation resistance of materials and components in order to prove its operability in challenging conditions.

The delivery included the renovation of the irradiator, replacement of the Co-60 source and delivery of the special vacuum system for testing the components in a wide range of temperatures and pressures.

The equipment is intended for tests of the radiation resistance of cables, electronics and other special components subsequently used in nuclear power plants or, e.g., in space applications.

 

 

 

 

BASIC PARAMETERS OF THE EQUIPMENT DELIVERED

  • Temperature range: -196°C to +400°C
  • High vacuum
  • Source activity: 200 TBq

 

 

 

 